Welcome to Shanghai HI RUN system control Co., Ltd!

Contact us Collection site Online Message

National Service Hotline 021-63526338
  • Home
  • About Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/about/ —— About Us {/dede:channel}
  • Product Center
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Product Center/ —— Product Center {/dede:channel}
  • News Information
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/News Information/ —— News Information {/dede:channel}
  • Engineering Case
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Engineering Case/ —— Engineering Case {/dede:channel}
  • Sales Outlets
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Sales Outlets/ —— Sales Outlets {/dede:channel}
  • Download
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /Download/ —— Download {/dede:channel}
  • Contact Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Contact Us/ —— Contact Us {/dede:channel}
  • Online Message

Hot keyword search:

German Standard (VDE) Location:Home> > English > Product Center > Mining Cables > German Standard (VDE) >

NTMCWOEU Flexible Medium-Voltage Single Core Cable

Article source:http://www.trcables.com/   author:上海嗨润   Release time:2018-02-02 15:25   Browse times:second

NTMCWOEU Flexible Medium-Voltage Single Core Cable

Applications

These cables are used for connection in switch-gear and for connection of mobile transformer substations to the overhead line.

Standards

VDE 0250 Part 813

Construction

NTMCWOEU Flexible Medium-Voltage Single Core Cable

Conductors: Flexible stranded tinned copper conductor, class 5 according to DIN VDE 0295.

Inner Conductor Layer: Special conductive rubber.

Insulation: EPR type 3GI3.

Outer Conductor Layer:Special conductive rubber.

Screen: Spiral of tinned copper wires.

  • Outer Sheath: PCP type 5GM3.

Dimensions and Weight

6/10kV

Number of Cores×Nominal Cross Section Insulation Thickness Thickness of Outer Sheath Nominal Overall Diameter Nominal Weight
No.×mm² mm mm mm kg/km
1×16/16 3.4 2.2 22.0 760
1×25/16 3.4 2.2 23.5 910
1×35/16 3.4 2.2 24.5 1040
1×50/16 3.4 2.2 27.0 1260
1×70/16 3.4 2.5 28.5 1530
1×95/16 3.4 2.5 30.5 1770
1×120/16 3.4 2.5 33.5 2180
1×150/25 3.4 3.0 35.0 2550
1×185/25 3.4 3.0 37.0 2900
1×240/25 3.4 3.5 41.0 3590
1×300/25 3.4 3.5 43.0 4280
1×400/35 3.4 4.0 46.0 5120
1×500/35 3.4 4.0 49.0 5950
1×630/35 3.4 4.0 53.5 7860

12/20kV

Number of Cores×Nominal Cross Section Insulation Thickness Thickness of Outer Sheath Nominal Overall Diameter Nominal Weight
No.×mm² mm mm mm kg/km
1×25/16 5.5 2.5 28.0 1180
1×35/16 5.5 2.5 29.5 1320
1×50/16 5.5 2.5 31.5 1560
1×70/16 5.5 3.0 34.0 1920
1×95/16 5.5 3.0 36.0 2190
1×120/16 5.5 3.0 38.0 2460
1×150/25 5.5 3.5 40.0 2990
1×185/25 5.5 3.5 42.0 3350
1×240/25 5.5 3.5 45.0 3990
1×300/25 5.5 3.5 48.0 4760
1×400/35 5.5 4.0 52.0 6100
1×500/35 5.5 4.0 56.0 7010
1×630/35 5.5 4.0 60.0 8180

14/25kV

Number of Cores×Nominal Cross Section Insulation Thickness Thickness of Outer Sheath Nominal Overall Diameter Nominal Weight
No.×mm² mm mm mm kg/km
1×25/16 6.8 3.0 30.5 1300
1×300/25 6.8 4.0 49.0 4900

18/30kV

Number of Cores×Nominal Cross Section Insulation Thickness Thickness of Outer Sheath Nominal Overall Diameter Nominal Weight
No.×mm² mm mm mm kg/km
1×50/16 8.0 3.0 35.0 1870

20/35 kV

Number of Cores×Nominal Cross Section Insulation Thickness Thickness of Outer Sheath Nominal Overall Diameter Nominal Weight
No.×mm² mm mm mm kg/km
1×95/16 9.5 3.5 44.0 2900
1×150/25 9.5 3.5 46.3 3600
1×240/25 9.5 4.0 51.7 5000